Radionuclide Identification Devices – wafer Altamioz https://wafer.com.sa/ Thu, 26 Oct 2023 14:15:15 +0000 en-US hourly 1 https://wafer.com.sa/wp-content/uploads/2023/08/Wafer-Altamioz-logo-05-2-150x150.png Radionuclide Identification Devices – wafer Altamioz https://wafer.com.sa/ 32 32 R225 https://wafer.com.sa/r225/ https://wafer.com.sa/r225/#respond Tue, 24 Oct 2023 14:19:34 +0000 https://wafer.com.sa/?p=1254

R225

Radiation

The identiFINDER® R225 is a rugged, pager-sized Spectroscopic Personal Radiation Detector (SPRD). The R225 features a single 18mm cubic CsI detector with SiPM (G/GN) providing exceptional sensitivity and identification capability. There is also an option for an LaBr(Ce) spectroscopic detector (LG/LGN) for ≤3.5% resolution. The device features the familiar three-button control common to all identiFINDER products. The R225 provides ANSI N42.48 SPRD compliance, as well as MSLTD 810g Salt/Fog compliance.

The R225 comes with key features built on feedback of its predecessor the identiFINDER R200 including operating in multiple languages. The screen has been upgraded for increased brightness and added color to be visible in sunlight and through polarized sunglasses. The holster has been modified to provide quick access to the device and for the screen to be completely visible while holstered. The battery can operate for over thirty hours with hot-swappable backups and built-in Bluetooth, Wi-Fi, and GPS ensure remote data viewing.

Related Products

]]>
https://wafer.com.sa/r225/feed/ 0
R430 https://wafer.com.sa/r430/ https://wafer.com.sa/r430/#respond Tue, 24 Oct 2023 14:16:31 +0000 https://wafer.com.sa/?p=1247

R430

Radiation

The MUVE™ R430 is a radiation detector designed for unmanned aerial systems (UAS) used to detect, locate, measure, map, and identify radioactive sources from above. The SkyRanger® R70 serves as the airframe for the R430. The R430 is integrated into the R70’s Mission Control Software (MCS) providing visible and audible alerts that expedite response measures. The R430 provides a balance of size and weight for various situations including survey, emergency response, and environmental monitoring.

Autonomous, Real-Time Radiation Detection

RAPID, AUTONOMOUS MONITORING

Automatically Analyzes Collected Data Against Extensive Library When Change In Background Radiation Is Detected. Radiation Source Is Identified Within Seconds.

SCALABLE AND EXPANDABLE ARCHITECTURE

Detection Units Available In Variety Of Sizes And Housing And Can Be Openly Installed Or Concealed For High-Consequence Threat Interdiction.

ADVANCED TEMPLATE MATCHING ALGORITHMS

Separates Innocent Material, Such As Medical Patients, From Threatening Sources - A Unique Feature Not Offered By Other Area Monitors.

SYSTEM OVERVIEW

Throughput : >100 Kcps Training Requirements: <10 Mins For Operator; 1/2 Day For Advanced User

EXPORTS RESTRICTIONS

The Information Contained In This Page Pertains To A Dual Use Product Controlled For Export By The Export Administration Regulations (EAR). Diversion Contrary To US Law Is Prohibited. US Department Of Commerce Authorization Is Not Required Prior To Export Or Transfer To Foreign Persons Or Parties Unless Otherwise Prohibited.

Related Products

]]>
https://wafer.com.sa/r430/feed/ 0
R700 https://wafer.com.sa/r700/ https://wafer.com.sa/r700/#respond Tue, 24 Oct 2023 14:07:53 +0000 https://wafer.com.sa/?p=1240

IdentiFINDER R700

Radiation

The identiFINDER R700 Backpack Radiation Detector (BRD) offers new spectroscopic broad-search capabilities. Once dismounted, the identiFINDER R700 provides the capabilities required to successfully perform wide-area searches quickly and efficiently while offering exceptional sensitivity, communication, and trusted spectroscopic algorithms in a lightweight, ergonomic form-factor.

Autonomous, Real-Time Radiation Detection

RAPID, AUTONOMOUS MONITORING

Automatically Analyzes Collected Data Against Extensive Library When Change In Background Radiation Is Detected. Radiation Source Is Identified Within Seconds.

SCALABLE AND EXPANDABLE ARCHITECTURE

Detection Units Available In Variety Of Sizes And Housing And Can Be Openly Installed Or Concealed For High-Consequence Threat Interdiction.

ADVANCED TEMPLATE MATCHING ALGORITHMS

Separates Innocent Material, Such As Medical Patients, From Threatening Sources - A Unique Feature Not Offered By Other Area Monitors.

SYSTEM OVERVIEW

Throughput : >100 Kcps Training Requirements: <10 Mins For Operator; 1/2 Day For Advanced User

EXPORTS RESTRICTIONS

The Information Contained In This Page Pertains To A Dual Use Product Controlled For Export By The Export Administration Regulations (EAR). Diversion Contrary To US Law Is Prohibited. US Department Of Commerce Authorization Is Not Required Prior To Export Or Transfer To Foreign Persons Or Parties Unless Otherwise Prohibited.

Related Products

]]>
https://wafer.com.sa/r700/feed/ 0
IdentiFINDER R900  https://wafer.com.sa/identifinder-r900/ https://wafer.com.sa/identifinder-r900/#respond Sun, 20 Aug 2023 12:09:59 +0000 https://wafer.com.sa/?p=426

IdentiFINDER R900

Radiation

The FLIR IdentiFINDER S900 Is An Autonomous Sensor That Delivers Real-Time Radiation Detection And Identification. It Detects The Presence Or Movement Of Radioactive Material Across Borders, Into Buildings, At Large Public Gatherings, And Events. The S900 Is Available In A Wide Variety Of Form Factors That Can Be Tailored To Application-Specific Environments And Sensitivities. Deployment Can Begin With A Standalone System And Expand To A Network Of Systems As Needs Change.

Autonomous, Real-Time Radiation Detection

RAPID, AUTONOMOUS MONITORING

Automatically Analyzes Collected Data Against Extensive Library When Change In Background Radiation Is Detected. Radiation Source Is Identified Within Seconds.

SCALABLE AND EXPANDABLE ARCHITECTURE

Detection Units Available In Variety Of Sizes And Housing And Can Be Openly Installed Or Concealed For High-Consequence Threat Interdiction.

ADVANCED TEMPLATE MATCHING ALGORITHMS

Separates Innocent Material, Such As Medical Patients, From Threatening Sources - A Unique Feature Not Offered By Other Area Monitors.

SYSTEM OVERVIEW

Throughput : >100 Kcps Training Requirements: <10 Mins For Operator; 1/2 Day For Advanced User

EXPORTS RESTRICTIONS

The Information Contained In This Page Pertains To A Dual Use Product Controlled For Export By The Export Administration Regulations (EAR). Diversion Contrary To US Law Is Prohibited. US Department Of Commerce Authorization Is Not Required Prior To Export Or Transfer To Foreign Persons Or Parties Unless Otherwise Prohibited.

Related Products

]]>
https://wafer.com.sa/identifinder-r900/feed/ 0
IdentiFINDER R500 https://wafer.com.sa/identifinder-r500/ https://wafer.com.sa/identifinder-r500/#respond Sun, 20 Aug 2023 12:03:20 +0000 https://wafer.com.sa/?p=420

IdentiFINDER R500

Radiation

The FLIR IdentiFINDER R500 Is An Extremely Sensitive And Accurate Digital Handheld Gamma Radionuclide Identification Device (RID). Available In Two Configurations (NaI And LaBr), The R500 Quickly Detects, Locates, Accurately Measures, And Identifies Radiation Sources. The Additional Detector Volume Allows It To Identify Radioactive Material Where Other Instruments Cannot. When Large Areas Need To Be Screened Rapidly Or There Is Potential For Shielding, The IdentiFINDER R500 Provides Superior Sensitivity And Performance.

Determine Nuclide Identity In Seconds

ENHANCED SENSITIVITY

Reduced Time To Locate Radioactive Source; Identification Algorithm (ANSI N42.34 Library) Reduces False Alarm And Nuisance Events

EASILY OPERATED

Common Operating Interface Provides Immediate Comfort When Using The Device; Spectroscopy Knowledge Not Required For Meaningful Operation

LIMITED MAINTENANCE REQUIRED

Automatic Calibration And Continuous LED Stabilization For Temperature Control And Other Conditional Changes; 5-Year Factory Maintenance Interval

SYSTEM OVERVIEW

Data Storage : 2GB Internalmemory; Up To 600,000 Spectra Training Requirements: <10minsfor Operator; 1 Dayfor Advanced User

EXPORTS RESTRICTIONS

The Information Contained In This Page Pertains To A Dual Use Product Controlled For Export By The Export Administration Regulations (EAR). Diversion Contrary To US Law Is Prohibited. US Department Of Commerce Authorization Is Not Required Prior To Export Or Transfer To Foreign Persons Or Parties Unless Otherwise Prohibited.

Related Products

]]>
https://wafer.com.sa/identifinder-r500/feed/ 0
IdentiFINDER R440 https://wafer.com.sa/identifinder-r440/ https://wafer.com.sa/identifinder-r440/#respond Sun, 20 Aug 2023 11:52:59 +0000 https://wafer.com.sa/?p=414

IdentiFINDER R440

Radiation

The FLIR IdentiFINDER R440 Is A Lightweight, Source-Less Radionuclide Identification Device (RID) That Delivers Sensitive Detection And Fast Results For Routine Survey Or Secondary Screening Response Missions. The R440 Is Available With NaIL, NaI, LaBr And CLLBC Detector Options To Respond To Radiological Threats From Farther Away, Behind Heavier Shielding, And With Better Resolution Than Similarly-Sized RIDs. The Extended Energy Range Provides Neutron Indication In The NaI (G) Version. Its Light Weight Makes Single-Handed Operation Easy During Extended Operations, While The IP67-Rated Enclosure Is Built To Survive. The Bold, Easy-To-Read Interface With 360° EasyFinder™ Mode Expedites Decision-Making To Keep Personnel And The Community Safe. Hot Swappable Batteries Facilitate Continuous Operation On Extended Missions And The Ability To Charge Batteries Outside On The Instrument While The Instrument Is On Standby Ensures Instant Readiness In The Response Vehicle.

Power Through Missions

HIGHER PERFORMANCE IN A RUGGED FORM FACTOR

Adding To The Advanced Spectroscopic Algorithm And Sensitivity Of The Original R440, The New Ruggedized R440 Adds Optional, Proven, Higher Resolution Detection Capability.

ABILITY TO POWER THROUGH MISSIONS

Power Flexibility With The New Hot Swappable Batteries Means The New R440 Will Go The Distance And Complete The Mission With You.

SITUATIONAL AWARENESS WHEN YOU NEED IT

When Threat Detection Occurs, Getting Results Communicated As Quickly As Possible Is Critical. The New R440 Makes Communications Easier Than Ever Before, No Matter The Method.

SYSTEM OVERVIEW

Threats : Detects Gamma And/Or Neutron Radiation Emitted From Natural Occurrences In The Environment, Special Nuclear Material, Industrial, Or Medical Material Technology : Radionuclide Identification Device (RID)

EXPORTS RESTRICTIONS

The Information Contained In This Page Pertains To A Dual Use Product Controlled For Export By The Export Administration Regulations (EAR). Diversion Contrary To US Law Is Prohibited. US Department Of Commerce Authorization Is Not Required Prior To Export Or Transfer To Foreign Persons Or Parties Unless Otherwise Prohibited.

Related Products

]]>
https://wafer.com.sa/identifinder-r440/feed/ 0
FLIR IdentiFINDER R425 https://wafer.com.sa/402-2/ https://wafer.com.sa/402-2/#respond Sun, 20 Aug 2023 11:31:26 +0000 https://wafer.com.sa/?p=402

IdentiFINDER R425

FLIR IdentiFINDER R425

Radiation

The FLIR IdentiFINDER R425 Is The Next Generation Of The Most Deployed Radionuclide Identification Device (RID), Offering 360-Degree Coverage So You Can Locate And Measure Gamma And Neutron Radioactive Sources With Confidence. It Builds On FLIR’s Trusted Algorithms With Advanced Heuristics And Hybrid Identification Techniques. With The Familiar IdentiFINDER User Interface And 3-Button Control, You Can Operate The R425 Quickly, Communicate Results, And Take Command Of Any Situation, In Any Environment, Remotely. When Other Systems Fail In Extremely High Gamma Fields, The FLIR IdentiFINDER R425 Provides Pinpoint Accuracy And Remains Fully Operational. The IdentiFINDER R425 Goes The Distance With Balanced Ergonomic Design, Unparalleled Ruggedness, Flexible Power Management, And Usability. The R425 Provides An Ideal Balance Of Size, Weight, And Performance For Various Missions Including Surveying, Emergency Response, And Environmental Monitoring.

Building On A Legacy Of Tried And Trusted Performance

BETTER DETECTION IN ALL DIRECTIONS

New Cubic Detector Design, Sourceless Stabilization, Advanced Heuristics, And Hybrid Identification Techniques Enable High Performance Detection In All Directions; 3x More Sensitive Gamma And 2x More Sensitive Neutron Detection.

POWER THROUGH YOUR MISSION

IP67-Rated, Ergonomic Design Is 15% Lighter Than Previous Generations, While The Exceptional 12-Hour Battery Life Provides The Right Balance For A Variety Of Missions.

SITUATIONAL AWARENESS AND SUPPORT WHEN YOU NEED IT

Remote Data Viewing, Operation, And Reach Back Is Made Possible Through Communication Features Including Dual USB-C Ports, FLIR's Trusted Web Interface, The FLIR RAD Mobile Application, And A Universal API That Enables Integration With User Deployed Networks.

SYSTEM OVERVIEW

Technology : Radionuclide Identification Device (RID) Gamma Detector – Nal [TI] : 1.77 X 1.77 X 1.77 In (45 X 45 X 45 Mm) Cubic Detector With Silicon Photomultiplier (SiPM)

EXPORTS RESTRICTIONS

The Information Contained In This Page Pertains To A Dual Use Product Controlled For Export By The Export Administration Regulations (EAR). Diversion Contrary To US Law Is Prohibited. US Department Of Commerce Authorization Is Not Required Prior To Export Or Transfer To Foreign Persons Or Parties Unless Otherwise Prohibited.

Related Products

]]>
https://wafer.com.sa/402-2/feed/ 0
IdentiFINDER R400 https://wafer.com.sa/identifinder-r400/ https://wafer.com.sa/identifinder-r400/#respond Sun, 20 Aug 2023 11:25:24 +0000 https://wafer.com.sa/?p=390

IdentiFINDER R400

Radiation

With Over 20,000 Devices Deployed Globally, The FLIR IdentiFINDER R400 Is The Most Widely Deployed Handheld Radionuclide Identification Device (RID) In The World. It Is Used To Detect, Locate, Measure, And Identify Radioactive Sources And Produces Rapid Visible, Audible, And Tactile Alerts That Expedite Response Measures. The IdentiFINDER R400 Provides Operators The Ideal Balance Of Size And Weight For A Wide Variety Of Monitoring Scenarios Including All-Purpose Surveying, Emergency Response, And Environmental Monitoring.

Detect, Locate, Measure, And Identify Radioactive Sources

GAMMA AND NEUTRON DETECTION

NaI Detector Enables Rapid Isotope Identification (ANSI N42.34 Library) For Threat Determination; GM Detector Provides Dose Rate And Total Dose

COMMON OPERATING INTERFACE

Large Display Provides Visual Alarm Confirmation And Ability To View Advanced Spectral Data; Self-Explanatory Buttons Provide Easy, One-Handed Operation

ADVANCED COMMUNICATIONS

Like Other IdentiFINDER Products, The R400 Contains On-Board Bluetooth, Web Server, And GPS Technologies

SYSTEM OVERVIEW

Data Storage :2GB Internal Memory; Up To 600,000 Spectra Training Requirements: < 10 Mins For Operator; 1 Day For Advanced User

EXPORTS RESTRICTIONS

The Information Contained In This Page Pertains To A Dual Use Product Controlled For Export By The Export Administration Regulations (EAR). Diversion Contrary To US Law Is Prohibited. US Department Of Commerce Authorization Is Not Required Prior To Export Or Transfer To Foreign Persons Or Parties Unless Otherwise Prohibited.

Related Products

]]>
https://wafer.com.sa/identifinder-r400/feed/ 0
IdentiFINDER R300 https://wafer.com.sa/identifinder-r300/ https://wafer.com.sa/identifinder-r300/#respond Sun, 20 Aug 2023 11:20:24 +0000 https://wafer.com.sa/?p=384

(AR) IdentiFINDER R300

Radiation

The FLIR IdentiFINDER R300 Is The World’s Highest Performing, Pager-Sized Spectroscopic Personal Radiation Detector (SPRD). It Provides Continuous Detection And Full Threat Identification (ANSI N42.48 Library). The Simple Two-Button User Interface Facilitates Expedited Threat Response. Visible, Audible, And Tactile Alarms Rapidly Alert The Operator Via The Easy-To-Read Color Display. On-Board Bluetooth, Web Server, And GPS Technologies Make Interagency Communication Easier Than Ever. The R300 Is Ideal For Belt-Worn Passive-Scanning, Security Checkpoints, Border Patrol, And First Response.

World's Best-Performing SPRD With High-Resolution

BELT-WORN, IDENTIFICATION-CAPABLE

Lightweight Spectrometer Delivers Gamma And Neutron Detection; Highest Detector Resolution In A Pager-Sized Device With Virtually No False Alarms

ONE TOUCH REACHBACK™

Immediately Send Full Spectroscopic Data, Device Information, Time, And GPS Location To Key Stakeholders With Single Push Of A Button

RUGGED DESIGN

Drop Tested To 1.5m; Uniquely Constructed Cadmium Zinc Telluride (CZT) Semi-Conductor Material Does Not Require Calibration Or Stabilization

SYSTEM OVERVIEW

Data Storage :2GB Internal Memory; Up To 600,000 Spectra Training Requirements:< 10 Mins For Operator; 1 Day For Advanced User

EXPORTS RESTRICTIONS

The Information Contained In This Page Pertains To A Dual Use Product Controlled For Export By The Export Administration Regulations (EAR). Diversion Contrary To US Law Is Prohibited. US Department Of Commerce Authorization Is Not Required Prior To Export Or Transfer To Foreign Persons Or Parties Unless Otherwise Prohibited.

Related Products

]]>
https://wafer.com.sa/identifinder-r300/feed/ 0
IdentiFINDER R200 https://wafer.com.sa/identifinder-r200/ https://wafer.com.sa/identifinder-r200/#respond Sun, 20 Aug 2023 08:56:19 +0000 https://wafer.com.sa/?p=372

IdentiFINDER R200

Radiation

FLIR IdentiFINDER R200 Instruments Are Rugged, Pager-Sized Spectroscopic Personal Radiation Detectors (SPRD). They Provide Full ANSI N42.32 Personal Radiation Detector (PRD) Compliance And Feature Next-Generation Solid State Detector Read-Out Technology That Delivers ANSI N42.48 SPRD Compliance With Nuclide Identification. The R200-G Detects And Identifies Gamma Radiation And The R200-GN Additionally Provides Neutron Detection Capability. Law Enforcement Agencies And First Responders Use The R200 During Routine Traffic Stops Or High Visibility Events And In Mass Transit Or Critical Infrastructure Entry Control Points. The OneTouch Reachback™ Feature Uses The Latest Advancements In Bluetooth® And Web Server Technologies To Provide Large-Scale Situational Awareness By Alerting Others Before Arriving On-Scene.

Identification-Capable Pager

RADIOISOTOPE IDENTIFICATION

Identifies Specific Gamma Source (R200-G And R200-GN) And Detects Neutron Source (R200-GN) Enabling Front-Line Responders To Quickly Determine Whether It Is A True Threat Or Benign.

PAGER-SIZED AND RUGGED

Weighs <1 Pound, Is 1.5m Drop-Tested, And IP67-Rated So Operators Can Wear It With Confidence During Daily Passive Radiation Monitoring.

SHARED COMMON USER INTERFACE

IdentiFINDER Products Share A Field-Proven User-Interface With Simple Data Presentation, Allowing For Quick Integration With Existing Protocols And A Reduced Training Burden.

SYSTEM OVERVIEW

Data Storage : 30MB Internal Memory; Up To 5,000 Spectra Training Requirements: < 10 Mins For Operator; 1 Day For Advanced User

Related Documents

 

EXPORTS RESTRICTIONS

The Information Contained In This Page Pertains To A Dual Use Product Controlled For Export By The Export Administration Regulations (EAR). Diversion Contrary To US Law Is Prohibited. US Department Of Commerce Authorization Is Not Required Prior To Export Or Transfer To Foreign Persons Or Parties Unless Otherwise Prohibited.

Related Products

]]>